Skip to content
Evologics America

EvoGraft Tendon Allografts

Tendon Grafts. Selected for the Reconstruction Plan.

EvoGraft provides human tendon allografts in multiple anatomic forms, processing options and bone-block configurations for sports medicine and orthopedic reconstruction.

  • Human tendon allografts
  • Multiple anatomic sources
  • Bone-block options
  • Irradiated and non-irradiated options
  • Allograft traceability
  • Case-specific availability
Bone-tendon-bone human tendon allograft on a dark studio surface

What are EvoGraft Tendons

Human tendon allografts for clinician-directed reconstruction

EvoGraft Tendons are human soft-tissue allografts supplied in a range of anatomic forms commonly evaluated for ligament and tendon reconstruction.

The portfolio includes tibialis, Achilles, bone-tendon-bone, gracilis, semitendinosus, quadriceps, patellar and peroneus longus grafts. Certain grafts are available with bone blocks or in pre-shaped configurations.

Tissue
Human tendon allograft
Selection
By anatomy, dimensions, processing method and bone configuration
Processing options
E-beam irradiated and PASCO₂-processed non-irradiated options
Availability
Dependent on donor anatomy and current inventory

Why graft selection matters

The graft is part of the surgical plan

Tendon allografts are not interchangeable inventory items. Selection may depend on reconstruction technique, desired length and diameter, fixation method, bone-block requirements and clinician preference.

  • Multiple anatomic sources

    Different tendon types provide distinct dimensions, shapes and handling characteristics.

  • Soft-tissue and bone-block options

    The portfolio includes soft-tissue-only grafts as well as Achilles and bone-tendon-bone configurations.

  • Processing choice

    Irradiated and non-irradiated options support selection aligned with clinician preference and institutional requirements.

  • Case coordination

    Evologics can assist with case-specific requests, donor-specific measurements and current inventory confirmation.

Available graft types

A portfolio built around reconstruction requirements

Explore tendon allograft configurations and SKUs organized by reconstruction requirement.

Achilles tendon allograft with attached bone block on a warm studio surface
Achilles tendon with bone block

Tibialis Anterior Tendon

A long soft-tissue tendon allograft available in irradiated and non-irradiated processing formats.

Tibialis Anterior Tendon catalog SKUs
SKUCatalog description
EV801FFTIBIALIS ANTERIOR TENDON, E BEAM
EVP801FFTIBIALIS ANTERIOR TENDON - NON IRRADIATED

Tibialis Posterior Tendon

A soft-tissue tendon option available in irradiated and non-irradiated processing formats.

Tibialis Posterior Tendon catalog SKUs
SKUCatalog description
EV841FFTIBIALIS POSTERIOR TENDON, E BEAM
EVP841FFTIBIALIS POSTERIOR TENDON - NON IRRADIATED

Achilles Strip

An Achilles-derived soft-tissue strip without an attached bone block.

Achilles Strip catalog SKUs
SKUCatalog description
EV189FFACHILLES STRIP, E BEAM
EVP189FFACHILLES STRIP - NON IRRADIATED

Achilles Tendon

Achilles-derived graft configurations with and without pre-shaping.

Achilles Tendon catalog SKUs
SKUCatalog description
EV289FFACHILLES TENDON, E BEAM PRE-SHAPED
EV290FFACHILLES TENDON, E BEAM
EVP290FFACHILLES TENDON - NON IRRADIATED

Whole Patellar Tendon

A whole patellar tendon graft configuration.

Whole Patellar Tendon catalog SKUs
SKUCatalog description
EV291FFWHOLE PATELLAR TENDON FF

Bone-Tendon-Bone, Hemi

A partial bone-tendon-bone graft configuration.

Bone-Tendon-Bone, Hemi catalog SKUs
SKUCatalog description
EV292FFBTB TENDON, HEMI, E BEAM
EVP292FFBTB TENDON, HEMI, NON IRRADIATED

Pre-Shaped Bone-Tendon-Bone

A prepared BTB configuration intended to reduce intraoperative graft preparation.

Pre-Shaped Bone-Tendon-Bone catalog SKUs
SKUCatalog description
EV293FFPRE-SHAPED BTB TENDON, E BEAM
EVP293FFPRE-SHAPED BTB TENDON - NON IRRADIATED

Peroneus Longus Tendon

A long soft-tissue tendon allograft available in irradiated and non-irradiated processing formats.

Peroneus Longus Tendon catalog SKUs
SKUCatalog description
EV294FFPERONEUS LONGUS, E BEAM
EVP294FFPERONEUS LONGUS - NON IRRADIATED

Quadriceps Tendon with Bone Block

Quadriceps tendon configurations with an attached bone block, including pre-shaped options.

Quadriceps Tendon with Bone Block catalog SKUs
SKUCatalog description
EV299FFPRE-SHAPED QUADRICEPS TENDON W/BLOCK, E BEAM
EVP295FFQUADRICEPS TENDON W/BLOCK, PASCO
EVP299FFPRE-SHAPED QUADRICEPS TENDON W/BLOCK, PASCO

Semitendinosus Tendon

A soft-tissue tendon graft commonly evaluated for folded or multi-strand constructs.

Semitendinosus Tendon catalog SKUs
SKUCatalog description
EV392FFSEMITENDINOSIS TENDON, E BEAM
EVP392FFSEMITENDINOSIS TENDON - NON IRRADIATED

Gracilis Tendon

A smaller-diameter soft-tissue tendon commonly considered in multi-strand reconstruction techniques.

Gracilis Tendon catalog SKUs
SKUCatalog description
EV393FFGRACILIS, E BEAM
EVP393FFGRACILIS - NON IRRADIATED

Semitendinosus and Gracilis Combination

A combined tendon configuration available in irradiated and non-irradiated formats.

Semitendinosus and Gracilis Combination catalog SKUs
SKUCatalog description
EV394FFSEMITENDINOSUS/GRACILIS COMBO FF
EVP394FFSEMITENDINOSIS/GRACILIS TENDON - NON IRRADIATED

Two processing pathways

PASCO₂ non-irradiated

PASCO₂ is a proprietary supercritical carbon-dioxide processing method designed to remove unwanted material while preserving relevant tissue characteristics. Products in this category are identified as non-irradiated.

E-beam irradiated

Selected tendon grafts are available with electron-beam irradiation. Exact irradiation parameters and processing information should be confirmed in the current product documentation.

Processing choice should be based on current labeling, facility requirements and clinician judgment. The availability of two processing formats does not imply that one is clinically superior.

Ordering and case support

From graft request to operating room

  1. 01

    Define

    Identify the tendon type, processing preference, bone-block requirement and dimensional criteria.

  2. 02

    Confirm

    Evologics confirms current inventory and available donor-specific measurements.

  3. 03

    Review

    Provide facility documentation, tissue-bank information and product records when required.

  4. 04

    Reserve

    Coordinate graft allocation and delivery for the scheduled procedure.

  5. 05

    Receive

    Verify shipping conditions, packaging integrity and product information upon receipt.

  6. 06

    Track

    Complete all required allograft tracking and implantation documentation.

FAQ

Common tendon-allograft questions

Which tendon types are available?

The current catalog includes anterior and posterior tibialis, Achilles strip, Achilles tendon, patellar, BTB, quadriceps, gracilis, semitendinosus, combination and peroneus longus configurations.

Are non-irradiated grafts available?

Yes. Selected tendon grafts are listed as PASCO₂-processed or non-irradiated allografts. Confirm processing for the individual SKU in current product documentation.

Are irradiated grafts available?

Yes. Selected configurations are available with e-beam irradiation. Confirm current processing information for the individual graft.

Can Evologics provide donor-specific measurements?

Available measurements and dimensional specifications can be confirmed during the graft-selection and ordering process.

Does Evologics guarantee a specific graft diameter?

Human tissue naturally varies. Required dimensions should be discussed when requesting or reserving a graft.

How are tendon allografts stored?

Storage and thawing requirements may vary by product. Follow the current product labeling and Instructions for Use.

Human tissue selected for a specific reconstruction

EvoGraft Tendons are human tissue allografts intended for use by qualified healthcare professionals according to current product labeling and Instructions for Use.

Procedure selection, graft choice, preparation, fixation and postoperative management remain the responsibility of the treating clinician. Product availability, dimensions, processing and storage requirements must be confirmed for the individual graft.

Current Instructions for Use and controlled product labeling govern if any website description differs from the controlled product documents.

Sports Medicine

Coordinate the right graft for the next case.

Connect with Evologics for current availability, processing options, graft measurements, facility documentation and case coordination.